Given that I had decided on HO scale, I had a limited amount of space to work in and a lot of operation I wanted to cram in there. I initially started with a single-level plan but realized I didn't have enough room for staging AND a decent main line length. So multi-level it was. I shifted to a two-level design with a helix, but the helix ate up so much space in the room that it was impractical. I finally settled on a two-level design with a long, steep "escalator" track to connect the two.
I did not use any published model railway track plans, since I was basing this on the real CN Dartmouth Subdivision. I did have to make some compromises to fit the trackage in the room:
- no space for a wye at Windsor Junction
- no double track east of Windsor Junction (fiction becomes reality, as the double track has been removed on the prototype)
- simplification of the Burnside Industrial Park trackage
- gypsum facility in Dartmouth moved to staging
Since operations was a high priority for me, I included lots of switching opportunities. I set up a spreadsheet with a list of industries, what car types they accepted, and the length of each siding. This gave me an idea of how many cars I would need for the layout and how much operation could take place in one operating session. I tried to base the industries on real ones, but had to make some adjustments to get a good mix of cars.
I designed two staging yards, one at each "end" of the CN main line that the NSER interchanges with. Given the size of the room, they could not be too long, but I could stage three or four 6-7 car trains (plus engine) in each yard. That would give me enough room for a passenger train in each direction, plus a couple of mainline freights.
The penalty for having a multi-level layout was the connecting track between levels. To avoid looping around the room too much I made the track fairly steep, hence the name "escalator" for it. I think the grade was a fairly constant 4%. It became a bit of a challenge to get trains up and down the escalator, as some engines were just not powerful enough to "make the grade". I expect that if I had continued with the layout for much longer it would have become an operational problem requiring double-heading most trains.
Another penalty for using a room of that size was the radius of the curves. I decided on a minimum of 18" radius, which fit well into the room but did not permit reliable operation of cars longer than 60 scale feet. That ruled out modern autoracks and containers, which is a real problem when you want to model modern railways. I never progressed enough on the railway for this to become a problem, but it would have been an issue.
In the end I had the following standards:
- Code 100 rail
- 18" minimum radius
- Peco medium radius switches for mainline, small radius for industrials and yards
- Two cabs for operation of two trains simultaneously
- Manual switch operation using Caboose Industries ground throws
In my next post I will share some photos of the layout at its most complete, just before tear-down.
Hello Patricia and welcome. I'm sorry this blog is not more active... my model trains are in a box right now but they will come out in a few months. Please visit my other blog www.traingeek.ca/blog to see the big trains. :)
ReplyDelete